Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 650
Filtrar
1.
Arch Endocrinol Metab ; 68: e230055, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38394157

RESUMO

Objective: To evaluate glycemic control according to the number of daily basal rates (BRs) in type 1 diabetes patients using continuous subcutaneous insulin infusion (CSII). Subjects and methods: Cross-sectional study of patients treated with an open-loop CSII for at least 6 months and using a flash glucose monitoring system. Patients were divided into 2 groups: group 1 (G1) and group 2 (G2), with ≤4 and >4 BRs/24h, respectively. The groups were compared regarding HbA1c, time in range (TIR), time above range (TAR), time below range (TBR), glucose management indicator (GMI), glucose variability and data related to hypoglycemia. Regression models were performed. Results: The study included 99 patients (n = 55 in G1; n = 44 in G2). Median (Interquartile range) overall age was 30 (17) years, with 19.5 (48) and 51 (77) months of CSII use, respectively. The median number of different BRs was 3 (2) for G1 and 6 (2) for G2. There were no differences concerning age, sex, educational stage, weight, and insulin analog used. G2 had longer disease duration, longer CSII use, and higher total basal daily dose/kg. No significant differences regarding HbA1c, median glucose, GMI, TIR, TAR, and CV were found. G2 patients had more hypoglycemia, more asymptomatic hypoglycemia, and higher TBR. After adjusting for potential confounders, G1 maintained a lower risk of asymptomatic hypoglycemia. Conclusion: Programming open-loop CSII devices with more than 4 BRs does not improve metabolic control. Additionally, it seems to be a risk factor for hypoglycemia and was an independent predictor for asymptomatic hypoglycemia.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Automonitorização da Glicemia , Estudos Transversais , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Sistemas de Infusão de Insulina/efeitos adversos
2.
Diabetes Technol Ther ; 26(S3): 97-101, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38377320

RESUMO

The use of automated insulin delivery (AID) has led to a decrease in the burden of diabetes, allowing for better sleep, decreased anxiety about hypoglycemia, and automatic corrections doses, and meal recognition algorithms have provided "forgiveness" for imprecise carbohydrate (CHO) entries and missed or late meal boluses. We provide a case report and review of the current literature assessing the effect of AID on the burden of meal bolus. The case also demonstrates how sensor and pump data provide insight into insulin bolus behavior, and access to integrated cloud-based data has allowed for virtual patient visits. Glucose sensor metrics provides time in range and time below range, and the sensor-derived glucose management indicator provides an assessment of the long-term risk of complications when a laboratory glycated hemoglobin is not available.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Hipoglicemia/prevenção & controle , Hipoglicemia/etiologia , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Regular Humana/uso terapêutico
3.
J Diabetes Complications ; 38(2): 108689, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38244326

RESUMO

AIMS: Automated insulin delivery systems improve blood glucose control in patients with type 1 diabetes (T1D). However, optimizing their performance requires patient's proper compliance to meal insulin bolus administration. We explored real-life prevalence of delayed prandial boluses (DBs) in adults with T1D on advanced technologies, and their association with glycemic control and fear of hypoglycemia (FH). METHODS: In the last two-week web-based reports of 152 adults with T1D on Hybrid Closed Loop Systems (HCLS) or Sensor Augmented Pump (SAP), DBs were identified when a steep increase in blood glucose occurred at CGM before the prandial bolus, and CGM metrics were evaluated. All participants completed an online questionnaire on FH. RESULTS: Mean DBs over two weeks were 10.2 ± 4.7 (M ± SD, range 1-23) and more frequent in women than men (11.0 ± 4.6 vs. 9.4 ± 4.7, p = 0.036). Participants with more DBs (>12) showed significantly lower Time-In-Range (62.4 ± 13.8 vs. 76.6 ± 9.0 %) than those with less DBs (<7.7), along with higher Time-Above-Range, GMI, and Coefficient-of-Variation (ANOVA, p < 0.001 for all). Participants with higher FH score showed more DBs (11.6 ± 5.0) than those in lower tertiles (9.57 ± 4.59 and 9.47 ± 4.45, ANOVA p = 0.045). CONCLUSIONS: In patients on advanced technologies, delayed boluses are extremely common, and associate with significantly worse glycemic control. Utmost attention is needed to bolus timing, mainly tackling fear of hypoglycemia.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Masculino , Adulto , Humanos , Feminino , Insulina/efeitos adversos , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Controle Glicêmico , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Glicemia , Insulina Regular Humana/uso terapêutico , Automonitorização da Glicemia , Medo
4.
Endocrine ; 84(1): 128-135, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38197988

RESUMO

AIMS: Both hyperglycaemia and large glycaemic variability are associated with worse outcomes in patients with Type 2 diabetes mellitus (T2DM), possibly causing sympatho-vagal imbalance and endothelial dysfunction. Continuous subcutaneous insulin injection (CSII) improves glycemic control compared to multiple daily insulin injections (MDI). We aimed to assess whether CSII may improve cardiac autonomic and vascular dilation function compared to MDI. METHODS: We enrolled T2DM patients without cardiovascular disease with poor glycaemic control, despite optimized MDI therapy. Patients were randomized to continue MDI (with multiple daily peripheral glucose measurements) or CSII; insulin dose was adjusted to achieve optimal target ranges of blood glucose levels. Patients were studied at baseline and after 6 months by: 1) flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of the brachial artery; 2) heart rate variability (HRV) by 24-hour ECG Holter monitoring (HM). 7-day continuous glucose monitoring (CGM) was performed in 9 and 8 patients of Group 1 and 2, respectively. RESULTS: Overall, 21 patients were enrolled, 12 randomized to CSII (Group 1) and 9 to MDI (Group 2). The daily dose of insulin and Hb1AC did not differ significantly between the 2 groups, both at baseline and at follow-up. Glucose variability showed some significant improvement at follow-up in the whole population, but no differences were observed between the 2 groups. Both FMD and NMD, as well as HRV parameters, showed no significant differences between the 2 groups at 6-month follow-up. CONCLUSIONS: In this randomized small study we show that, in T2DM patients, CSII achieves a similar medium-term glycemic control compared to MDI, without any adverse effect on the cardiovascular system.


Assuntos
Doenças Autoimunes , Sistema Cardiovascular , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hiperglicemia , Humanos , Insulina , Hipoglicemiantes/efeitos adversos , Automonitorização da Glicemia , Glicemia , Hiperglicemia/tratamento farmacológico , Injeções Subcutâneas , Sistemas de Infusão de Insulina/efeitos adversos
5.
J Diabetes Sci Technol ; 18(2): 318-323, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37966051

RESUMO

BACKGROUND: With automated insulin delivery (AID) systems becoming widely adopted in the management of type 1 diabetes, we have seen an increase in occurrences of rebound hypoglycemia or generated hypoglycemia induced by the controller's response to rapid glucose rises following rescue carbohydrates. Furthermore, as AID systems aim to enable complete automation of prandial control, algorithms are designed to react even more strongly to glycemic rises. This work introduces a rebound hypoglycemia prevention layer (HypoSafe) that can be easily integrated into any AID system. METHODS: HypoSafe constrains the maximum permissible insulin delivery dose based on the minimum glucose reading from the previous hour and the current glucose level. To demonstrate its efficacy, we integrated HypoSafe into the latest University of Virginia (UVA) AID system and simulated two scenarios using the 100-adult cohort of the UVA/Padova T1D simulator: a nominal case including three unannounced meals, and another case where hypoglycemia was purposely induced by an overestimated manual bolus. RESULTS: In both simulation scenarios, rebound hypoglycemia events were reduced with HypoSafe (nominal: from 39 to 0, hypo-induced: from 55 to 7) by attenuating the commanded basal (nominal: 0.27U vs. 0.04U, hypo-induced: 0.27U vs. 0.03U) and bolus (nominal: 1.02U vs. 0.05U, hypo-induced: 0.43U vs. 0.02U) within the 30-minute interval after treating a hypoglycemia event. No clinically significant changes resulted for time in the range of 70 to 180 mg/dL or above 180 mg/dL. CONCLUSION: HypoSafe was shown to be effective in reducing rebound hypoglycemia events without affecting achieved time in range when combined with an advanced AID system.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Pâncreas Artificial , Adulto , Humanos , Hipoglicemiantes/efeitos adversos , Pâncreas Artificial/efeitos adversos , Glicemia , Automonitorização da Glicemia/métodos , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemia/induzido quimicamente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/efeitos adversos , Glucose/efeitos adversos
6.
Diabetes Technol Ther ; 26(1): 24-32, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37782904

RESUMO

Objective: Severe hypoglycemia (SH) and diabetic ketoacidosis (DKA) remain significant risks with intensive insulin therapy. While these adverse event (AE) rates are generally very low in advanced hybrid closed-loop (AHCL) clinical studies, prospectively collected real-world AE rates are lacking. Research Design and Methods: The Control-IQ Observational (CLIO) study was a single-arm, prospective, longitudinal, postmarket surveillance study of individuals with type 1 diabetes (T1D) age 6 years and older who began the use of t:slim X2 insulin pump with Control-IQ technology in the real-world outpatient setting. AEs were reported monthly over 12 months and were compared to historical data from the T1D Exchange. Patient-reported outcomes were assessed quarterly. All study visits were virtual. Results: Three thousand one hundred fifty-seven participants enrolled from August 2020 through March 2022. Two thousand nine hundred ninety-eight participants completed through 12 months. SH rates were significantly lower than historic rates for children (9.31 vs. 19.31 events/100 patient years, d = 0.29, P < 0.01) and adults (9.77 vs. 29.49 events/100 patient years, d = 0.53, P < 0.01). DKA rates were also significantly lower in both groups. Lower observed rates of AEs occurred independent of baseline hemoglobin A1c or prior insulin delivery method. Time in range 70-180 mg/dL was 70.1% (61.0-78.8) for adults, 61.2% (52.4-70.5) for age 6-13, 60.9% (50.1-71.8) for age 14-17, and 67.3% (57.4-76.9) overall. Reduction in diabetes burden was consistently reported. Conclusions: SH and DKA rates were lower for users of t:slim X2 with Control-IQ technology compared to historical data for both adults and children. Real-world use of this AHCL system proved safe and effective in this virtual study design. The study was registered at clinicaltrials.gov (NCT04503174).


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Hipoglicemia , Criança , Adulto , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicações , Estudos Prospectivos , Cetoacidose Diabética/induzido quimicamente , Cetoacidose Diabética/epidemiologia , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Insulina/efeitos adversos , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemiantes/efeitos adversos , Glicemia
8.
Diabetes Obes Metab ; 26(3): 937-949, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38151748

RESUMO

AIM: To report on the effectiveness and safety of the MiniMed 780G automated insulin delivery system in real-world users during the month of Ramadan. MATERIALS AND METHODS: CareLink Personal data were extracted from MiniMed 780G system users from the Gulf region. Users were included if they had ≥10 days of sensor glucose data during the month of Ramadan 2022 as well as in the month before and after. For the main analysis, continuous glucose monitoring endpoints were aggregated per month and were reported by time of day (daytime: 05.31-18.00 h, and night-time). Additional analyses were performed to study the pace at which the algorithm adapts. RESULTS: Glycaemic control was well kept in the 449 included users (mean sensor glucose = 152.6 ± 18.7 mg/dl, glucose management indicator = 7.0 ± 0.4%, time in range = 70.7 ± 11.0%, time below 70 mg/dl = 2.3 ± 2.3%). Albeit some metrics differed from the month before (p < .0001 for all), absolute differences were very small and considered clinically irrelevant. During Ramadan, there was no increased risk of hypoglycaemia during daytime (time below 70 mg/dl = 2.3 ± 2.4%), time in range was highest during daytime (80.0 ± 10.7%, night: 60.4 ± 15.3%), while time above 180 mg/dl was highest during night-time (37.3 ± 16.3%, day: 17.7 ± 10.7%). The algorithm adapted immediately upon lifestyle change. CONCLUSION: The MiniMed 780G automated insulin delivery system is effective, safe and fast in adapting to the substantial changes that occur in the lifestyle of people with type 1 diabetes during Ramadan.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Insulina/efeitos adversos , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemiantes/efeitos adversos
9.
Diabetes Care ; 47(3): 384-392, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38128075

RESUMO

OBJECTIVE: To compare the risk of fetal overgrowth and preterm delivery in pregnant women with type 1 diabetes (T1D) treated with insulin pumps versus multiple daily injections (MDI) and examine whether possible differences were mediated through improved glycemic control or gestational weight gain during pregnancy. RESEARCH DESIGN AND METHODS: The risk of pregnancy and perinatal outcomes were evaluated in a cohort of 2,003 pregnant women with T1D enrolled from 17 countries in a real-world setting during 2013-2018. RESULTS: In total, 723 women were treated with pumps and 1,280 with MDI. At inclusion (median gestational weeks 8.6 [interquartile range 7-10]), pump users had lower mean HbA1c (mean ± SD 50.6 ± 9.8 mmol/mol [6.8 ± 0.9%] vs. 53.6 ± 13.8 mmol/mol [7.1 ± 1.3%], P < 0.001), longer diabetes duration (18.4 ± 7.8 vs. 14.4 ± 8.2 years, P < 0.001), and higher prevalence of retinopathy (35.3% vs. 24.4%, P < 0.001). Proportions of large for gestational age (LGA) offspring and preterm delivery were 59.0% vs. 52.2% (adjusted odds ratio [OR] 1.36 [95% CI 1.09; 1.70], P = 0.007) and 39.6% vs. 32.1% (adjusted OR 1.46 (95% CI 1.17; 1.82), P < 0.001), respectively. The results did not change after adjustment for HbA1c or gestational weight gain. CONCLUSIONS: Insulin pump treatment in pregnant women with T1D, prior to the widespread use of continuous glucose monitoring or automated insulin delivery, was associated with a higher risk of LGA offspring and preterm delivery compared with MDI in crude and adjusted analyses. This association did not appear to be mediated by differences in glycemic control as represented by HbA1c or by gestational weight gain.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Gestacional , Ganho de Peso na Gestação , Nascimento Prematuro , Recém-Nascido , Feminino , Gravidez , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Hemoglobinas Glicadas , Automonitorização da Glicemia , Macrossomia Fetal/epidemiologia , Glicemia , Insulina/efeitos adversos , Aumento de Peso , Injeções Subcutâneas , Hipoglicemiantes/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos
10.
Diabetes Technol Ther ; 25(12): 893-901, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37956265

RESUMO

Background: Evaluate the impact of the MiniMed™ 780G advanced hybrid closed-loop (AHCL) system on the glucose profile of pregnant women with type 1 diabetes (T1D) and maternal-neonatal complications. Methods: From April 2021 to September 2022, pregnant women with T1D treated with the AHCL system were included in an observational multicenter retrospective study. Continuous glucose monitoring parameters were analyzed monthly during pregnancy as well as maternal-neonatal complications. Results: Thirteen pregnant women, including a twin pregnancy (age: 33 ± 3 years, hemoglobin A1c [HbA1c]: 7.3% ± 0.7%, insulin doses: 0.72 ± 0.21 U/kg/day) were analyzed. At delivery, gestational age was 37 ± 2 weeks. During first 2 weeks of pregnancy, time in range (TIR, 63-140 mg/dL) was 46% (34-55) and increased to 54% (51-59) (P < 0.01), 64% (48-68) (P < 0.01), and 66% (60-70) (P < 0.001) during the first, second, and third trimester, respectively. During the night, TIR (63-140 mg/dL) was >70% throughout pregnancy. Time below the range <63 mg/dL increased from 0.5% (0-2) to 1.3% (0.7-2.2), 2% (1.2-3.5) (P < 0.05), and 1.3% (1.31-3) (P < 0.05) during the first, second, and third trimester, respectively. At delivery, insulin doses increased to 0.89 ± 0.35 IU/kg/day (P < 0.01), and HbA1c decreased to 6.4% ± 0.6% (P = 0.005). The reported carbohydrate amount increased from 167 ± 363 g/d during early pregnancy to 243 ± 106 g/d (P < 0.01) at delivery. The birthweight was 3134 ± 711 g, with 5/14 macrosomia and 2/14 neonatal hypoglycemia. Moreover, 5/13 patients had a preeclampsia and 9/13 a cesarean section, including three cases of scarred uterus. The Clinical Trial Registration number is: CE-2022-55. Conclusion: The AHCL system provided good glucose control during pregnancy and recommendation targets were reached during the nocturnal period only. The maternal and neonatal complications remained high.


Assuntos
Diabetes Mellitus Tipo 1 , Gravidez em Diabéticas , Adulto , Feminino , Humanos , Recém-Nascido , Gravidez , Glicemia , Automonitorização da Glicemia , Cesárea , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina/efeitos adversos , Gravidez em Diabéticas/tratamento farmacológico , Gestantes , Estudos Retrospectivos
11.
N Engl J Med ; 389(17): 1566-1578, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37796241

RESUMO

BACKGROUND: Hybrid closed-loop insulin therapy has shown promise for management of type 1 diabetes during pregnancy; however, its efficacy is unclear. METHODS: In this multicenter, controlled trial, we randomly assigned pregnant women with type 1 diabetes and a glycated hemoglobin level of at least 6.5% at nine sites in the United Kingdom to receive standard insulin therapy or hybrid closed-loop therapy, with both groups using continuous glucose monitoring. The primary outcome was the percentage of time in the pregnancy-specific target glucose range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]) as measured by continuous glucose monitoring from 16 weeks' gestation until delivery. Analyses were performed according to the intention-to-treat principle. Key secondary outcomes were the percentage of time spent in a hyperglycemic state (glucose level >140 mg per deciliter), overnight time in the target range, the glycated hemoglobin level, and safety events. RESULTS: A total of 124 participants with a mean (±SD) age of 31.1±5.3 years and a mean baseline glycated hemoglobin level of 7.7±1.2% underwent randomization. The mean percentage of time that the maternal glucose level was in the target range was 68.2±10.5% in the closed-loop group and 55.6±12.5% in the standard-care group (mean adjusted difference, 10.5 percentage points; 95% confidence interval [CI], 7.0 to 14.0; P<0.001). Results for the secondary outcomes were consistent with those of the primary outcome; participants in the closed-loop group spent less time in a hyperglycemic state than those in the standard-care group (difference, -10.2 percentage points; 95% CI, -13.8 to -6.6); had more overnight time in the target range (difference, 12.3 percentage points; 95% CI, 8.3 to 16.2), and had lower glycated hemoglobin levels (difference, -0.31 percentage points; 95% CI, -0.50 to -0.12). Little time was spent in a hypoglycemic state. No unanticipated safety problems associated with the use of closed-loop therapy during pregnancy occurred (6 instances of severe hypoglycemia, vs. 5 in the standard-care group; 1 instance of diabetic ketoacidosis in each group; and 12 device-related adverse events in the closed-loop group, 7 related to closed-loop therapy). CONCLUSIONS: Hybrid closed-loop therapy significantly improved maternal glycemic control during pregnancy complicated by type 1 diabetes. (Funded by the Efficacy and Mechanism Evaluation Program; AiDAPT ISRCTN Registry number, ISRCTN56898625.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Gravidez em Diabéticas , Adulto , Feminino , Humanos , Gravidez , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Gravidez em Diabéticas/sangue , Gravidez em Diabéticas/tratamento farmacológico , Resultado do Tratamento
12.
Diabetes Res Clin Pract ; 204: 110922, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37769906

RESUMO

AIMS: To evaluate the incidence of the skin reactions secondary to continuous subcutaneous insulin infusion (CSII) or continuous glucose monitoring (CGM), sensors and the characteristics of affected children with type 1 diabetes. METHODS: An observational, retrospective, single-centre study included 198 children with type 1 diabetes, (46% girls, mean age 11.75 years). A standardised questionnaire was completed with the patient during current care to evaluate the skin reactions (mean and percentage), the type of reaction, their impact and the treatment) and the characteristics of affected children with univariate and multivariate analysis. RESULTS: Sixty-seven children (33.8%) reported active skin reactions: 45 children with CSII (30.4%) and 46 with CGM (23.5%). Children with skin reactions were younger (mean age 10.6 yo versus 12.34 yo, p < 0.05), with a younger age at the diagnosis of diabetes (5.59 yo versus 7.08 yo, p < 0.05). Atopy was more frequent in the group with skin reactions (76.1% versus 54.1% p < 0.05). On multivariate analysis, only the personal history of atopy was associated with skin reactions: OR 2.56 [1.16-5.97] (p < 0.05). CONCLUSION: This study confirms the high incidence of skin reactions to adhesive devices used in the treatment of type 1 diabetes in children.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Feminino , Humanos , Criança , Masculino , Insulina/efeitos adversos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Hipoglicemiantes/efeitos adversos , Automonitorização da Glicemia , Incidência , Estudos Retrospectivos , Glicemia , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos
13.
J Diabetes Sci Technol ; 17(6): 1433-1439, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37449762

RESUMO

BACKGROUND: DBLG1 (Diabeloop Generation 1) stands as one of the five commercially available closed-loop solution worldwide for patients with type 1 diabetes as of 2023. Our aim was to provide an overview of all data obtained with this system regarding outcomes and populations, with an emphasis on interoperability. METHODS: This report includes all available sources of data (three randomized control trials and five surveys on real-life data). Collection ran from March 3, 2017 to April 30, 2022. RESULTS: We gathered data from 6859 adult patients treated with closed-loop from three to 12 months. Overall, all sources of data showed that time in range (TIR) 70 to 180 mg/dL, starting from 47.4% to 56.6%, improved from 12.2 to 17.3 percentage points. Time in hypoglycemia was reduced by 48% in average (range: 26%-70%) and reached a level of 1.3% in the largest and most recent cohort. In patients with excessive time in hypoglycemia at baseline (≥5%), closed-loop allowed a reduction in time below range (TBR) by 59%. The comparison of days with declared physical activity versus days without physical activity did not show differences in TBR. The improvement in TIR observed with three different pump systems (Vicentra Kaleido, n = 117; Sooil Dana-I, n = 84; and Roche Insight, n = 6684) ranged from 15.4 to 17.3 percentage points. DISCUSSION: These data obtained in different European countries were consistent throughout all reports, showing that this closed-loop system is efficient (high improvement in TIR), safe (remarkably low level of TBR), and interoperable (three pump settings so far).


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Glicemia , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemia/induzido quimicamente , Insulina Regular Humana/uso terapêutico
14.
Int J Mol Sci ; 24(13)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37445875

RESUMO

Skin adverse reactions to diabetes medical devices have been reported frequently over recent years. Adhesives attaching glucose sensors and continuous insulin infusion sets to the skin are proven to cause both allergic contact dermatitis and irritant contact dermatitis in patients with diabetes mellitus. Several allergens contained in adhesives and/or parts of medical devices are documented to cause allergic contact dermatitis, with acrylate chemicals being the most common culprit-especially isobornyl acrylate (IBOA), but also 2,2'-methylenebis(6-tert-butyl-4-methylphenol) monoacrylate or cyanoacrylates. Epoxy resin, colophonium and nickel were also identified as causative allergens. However, repetitive occlusion, maceration of the skin and resulting disruption of the skin barrier seem to have an impact on the development of skin lesions as well. The purpose of this study is to highlight the burden of contact dermatitis triggered by diabetes medical devices and to show possible mechanisms responsible for the development of contact dermatitis in a group of diabetic patients.


Assuntos
Dermatite Alérgica de Contato , Diabetes Mellitus , Humanos , Automonitorização da Glicemia , Diabetes Mellitus/etiologia , Dermatite Alérgica de Contato/etiologia , Alérgenos/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Acrilatos/efeitos adversos , Adesivos
15.
Exp Clin Endocrinol Diabetes ; 131(10): 539-547, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37473769

RESUMO

BACKGROUND: We previously published an algorithm predicting 24 h basal insulin infusion profiles in insulin pump-treated subjects with type 1 diabetes profiles from six subject characteristics. This algorithm was to be externally validated in an independent environment and patient population. METHODS: Thirty-two patients with pump-treated type diabetes were switched to their individually algorithm-derived basal insulin infusion profile, and the appropriateness of fasting glycemic control was scrutinized by means of a supervised 24 h fast. Primary endpoint was appropriate fasting glycemic control according to pre-defined criteria in at least 80% of the cohort. RESULTS: In 24 out of 32 patients switching to the algorithm-derived basal insulin infusion rate and undergoing a 24-h fasting period, appropriate glycemic control was achieved (=75%, lower than the pre-defined threshold of 80%), two patients discontinued the fast due to hyperglycemia, and six finished the fasting period, however, with inappropriate fasting glycemic control (entirely due to hyperglycemic episodes). There were no obvious differences in baseline characteristics between those with appropriate vs. inappropriate fasting glycemic control on the basal insulin infusion rate provided by the algorithm. CONCLUSION: In conclusion, when testing fasting glycemic control with an algorithm-derived individual basal insulin infusion profile during a 24 h fasting period in a cohort unrelated in terms of the hospital environment and catchment area, the success rate was lower than a pre-defined threshold for concluding utility of this algorithm. Therefore, applying this algorithm in order to initiate or optimize basal insulin infusion profiles in type 1 diabetes cannot be generally recommended.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/etiologia , Glicemia , Estudos Prospectivos , Insulina , Sistemas de Infusão de Insulina/efeitos adversos , Algoritmos , Hipoglicemiantes
17.
Endocr J ; 70(7): 677-685, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37019657

RESUMO

Prevention of hypoglycemia is an important strategy for glycemic management in patients with type 1 diabetes mellitus (T1D). Hypoglycemia is difficult to recognize at night while sleeping, particularly when using multiple daily injection (MDI) insulin therapy rather than sensor-augmented insulin-pump therapy. Therefore, it is possible that patients with T1D are at higher risk of nocturnal hypoglycemia when insulin is administered using an MDI regimen. We investigated nocturnal hypoglycemia in 50 pediatric patients with T1D on MDI insulin therapy using data from an intermittently scanned continuous glucose monitoring (isCGM) system. Hypoglycemia was observed on 446 of the 1,270 nights studied. Most of the hypoglycemic episodes were severe (blood glucose <54 mg/dL). On nights when hypoglycemia occurred, the blood glucose concentrations measured using finger-stick blood glucose monitoring (FSGM) before sleep and the next morning were lower than nights when hypoglycemia did not occur. However, few values were below the normal blood glucose range, suggesting that FSGM alone may be insufficient to detect nocturnal hypoglycemia. Approximately 7% of time was spent below the normal glucose range during the 10 hours from 21:00 to 7:00 the next morning. This result suggests that the patients on MDI insulin therapy could end up spending more time in hypoglycemia than is recommended by the American Diabetes Association (time below range <4.0% of time per day). Monitoring glucose levels overnight using an isCGM sensor may improve glycemic management via automatic detection of blood glucose peaks and troughs.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Criança , Glicemia , Automonitorização da Glicemia , Hipoglicemiantes/efeitos adversos , População do Leste Asiático , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos
18.
Acta Diabetol ; 60(7): 943-949, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37010594

RESUMO

BACKGROUND AND AIMS: Evidence supports the efficacy and safety of the Hybrid Close loop (HCL) system in patients with type 1 diabetes (T1D). However, limited data are available on the long-term outcomes of patients on HCL with telemedicine follow-up. METHODS: A prospective observational cohort study including T1D patients, who were upgrading to HCL system. Virtual training and follow-up were done through telemedicine. CGM data were analyzed to compare the baseline time in range (TIR), time below range (TBR), glycemic variability and auto mode (AM), with measurements performed at 3, 6 and 12 months. RESULTS: 134 patients were included with baseline A1c 7.6% ± 1.1. 40.5% had a severe hypoglycemia event in the last year. Baseline TIR, measured two weeks after starting AM was 78.6 ± 9.94%. No changes were evident at three (Mean difference - 0.15;CI-2.47,2.17;p = 0.96), six (MD-1.09;CI-3.42,1.24;p = 0.12) and 12 months (MD-1.30;CI-3.64,1.04;p = 0.08). No significant changes were found in TBR or glycemic variability throughout the follow-up. Use of AM was 85.6 ± 17.5% and percentage of use of sensor was 88.75 ± 9.5% at 12 months. No severe hypoglycemic (SH) events were reported. CONCLUSIONS: HCL systems allow to improve TIR, TBR and glycemic variability safely, early and sustained up to 1 year of follow-up in patients with T1D and high risk of hypoglycemia followed through telemedicine.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Telemedicina , Humanos , Diabetes Mellitus Tipo 1/etiologia , Insulina/uso terapêutico , Glicemia , Estudos Prospectivos , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemiantes/uso terapêutico , Hipoglicemia/etiologia , Hipoglicemia/induzido quimicamente , Automonitorização da Glicemia
19.
Diabetes Technol Ther ; 25(8): 559-570, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37053533

RESUMO

The introduction of continuous subcutaneous insulin infusion in clinical care has led to more optimal glycemic and quality-of-life outcomes, compared with multiple daily injections (MDI). Despite this, some insulin pump users revert back to MDI. The aim of this review was to include the most recent rates of insulin pump discontinuation among people with type 1 diabetes and to identify reasons for and factors associated with discontinuation. A systematic literature search was conducted using the Embase.com, MEDLINE (via OVID), PsycINFO, and CINAHL databases. Titles and abstracts of eligible publications were screened, and baseline characteristics of the included studies were extracted, as were variables in the context of insulin pump use. Data were synthesized into themes: indications for insulin pump initiation, persons with type 1 diabetes (PWD)-reported reasons for, and factors associated with insulin pump discontinuation. A total of 826 eligible publications were identified and 67 were included. Discontinuation percentages ranged from 0% to 30% (median 7%). The most frequently mentioned reasons for discontinuation were wear-related issues (e.g., device attached to the body, interference with daily activities, discomfort, affected body image). Related factors included hemoglobin A1c (HbA1c) (17%), issues with following treatment recommendations (14%), age (11%), gender (9%), side effects (7%), and comorbidity- and complication-related factors (6%). Despite many developments in insulin pump technology, discontinuation rates and PWD-reported reasons for and factors associated with insulin pump discontinuation in more recent studies were comparable to earlier reviews/meta-analyses. Continuation of insulin pump treatment depends on a knowledgeable and willing health care provider (HCP) team and a close match with PWDs' wishes and needs.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Prevalência , Insulina/uso terapêutico , Hemoglobinas Glicadas , Injeções , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemiantes/uso terapêutico , Injeções Subcutâneas
20.
N Engl J Med ; 388(11): 991-1001, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36920756

RESUMO

BACKGROUND: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear. METHODS: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes. RESULTS: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Criança , Pré-Escolar , Humanos , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...